Dynamic Cooking Systems 13031 Oven Thermostat 3/16" x 11-3/16" 48" Cap
Specifications:
| Attribute | Details |
|---|---|
| Viewed From Rear | See "Bj Outlet Positions" |
| W/ By-Pass Adj At Top & Gas Inlet Down | |
| [ Bjwa T'Stat 1/4" Npt ] [ Temp Low-500 ] | |
| [ Bulb 3/16" X 11-3/16" ] [ Cap 48" ] [ Out "C" Rear, | |
| [ Rotation 0 Degrees Body Down ] | |
| Dcs Knob # 22-1163 [ 2" Dia ] [ Off-Low-250-500] [Mount | |
| 11/16"][Notch Down], 1-3/16" Protrusion | |
| Dynamic Cooking Systems | |
| Oven Range - Oven Section. |
Description
More Information:
- DYNAMIC COOKING SYSTEMS:13031 ,55763-01 ,55763-02 ,55763-1 ,55763-2 ,55764-01 ,55764-02 ,55764-1 ,55764-2
Step1: Turn off power and gas supply to the oven before servicing.
Step2: Remove the control panel and locate the existing thermostat.
Step3: Disconnect the wiring and carefully remove the sensing bulb and capillary tube.
Step4: Install the new Thermostat in the same position.
Step5: Route the capillary tube safely and secure the sensing bulb.
Step6: Reconnect the wiring and mounting hardware.
Step7: Restore power and gas supply, then test oven temperature control.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Dynamic Cooking Systems 13031 Thermostat?
Regularly inspect the oven thermostat, capillary tube, and sensing bulb for damage or kinks. Keep the control area clean from grease buildup and ensure secure gas connections. Proper maintenance assists in maintaining accurate temperature control and prevents unsafe overheating conditions.
-
What are common issues with the Dynamic Cooking Systems 13031 Thermostat?
- Inaccurate or fluctuating temperature control.
- Oven failure to regulate gas flow properly.
- Kinked or damaged capillary tube.
- Unresponsive or sticking thermostat dial.
- Delayed heating or overheating conditions.