Hobart 14268 Thermocouple
Specifications:
| Attribute | Details |
|---|---|
| 1980 Series Snap Fit 18" Thermocouple, 20-30 Mv | |
| American Permanent Ware Griddle Ggm, Ggt | |
| Comstock Castle Oven Bake, Barbeque & Pizza Ovens. | |
| Series | C, D, F, K. |
| Dynamic Cooking Systems Oven All | |
| Garland Broiler 6-40/50S, 7-40/50S, 8-40/50S, 60-40/50R | |
| Oven Series | H281, P280. Standard Oven From 03/99 In |
| Canada Only, Range | G20-Sph |
| Imperial Model? | |
| Star Fryer M14, Mi4 (D,Dl), M18, Mi8(D,Dl), M43, 215B, 216, | |
| 403 404 | |
| Us Range Oven P-4-20. | |
| Wolf Oven Ch, Chssd, R |
Description
More Information:
- AMERICAN RANGE:10485 ,A11100 ,AMRA11100||ANETS:ANEP8900-32 ,P8900-32||APW WYOTT:1473103 ,AS-1473103||CECILWARE:F002A ,F002F ,GMF002A ,GMF002F||COMSTOCK CASTLE:17005 ,COM17005 ,COMT46 ,T46||DYNAMIC COOKING SYSTEMS:13007 ,13007-01||GARLAND:1019418 ,1029410 ,1307401 ,1415000 ,227002 ,227122 ,227183 ,4518817 ,G01575-1 ,GL1019418 ,GL1029410 ,GL1415000 ,GL227183 ,GLG01575-1||HOBART:00-920325 ,14268 ,412788-1 ,714268 ,920325||IMPERIAL:1121 ,30030 ,IMP1121||JADE RANGE:460-126-000 ,4612600000 ,4620100000||ROYAL RANGE:2175 ,2179||SOUTHBEND:1163868 ,1683868 ,SOU1163868 ,SOU1683868||STAR MFG:2J-6726 ,2J6726 ,6726 ,H456||STERO:STA2J-6726 ,STA2J6726 ,STA6726 ,STAH456||TRI-STAR:310210 ,TRS310210||U-LINE:1980-018||VULCAN HART:00-920325 ,14268 ,412788-1 ,714268 ,920325
Step1: Shut off gas and electrical power and allow unit to cool completely before servicing.
Step2: Remove access panel and disconnect old thermocouple from control valve.
Step3: Install new thermocouple into pilot bracket ensuring correct positioning in flame path.
Step4: Route lead and reconnect to safety control terminals securely.
Step5: Reassemble panels, restore power, and light pilot to test flame sensing.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Hobart 14268 Thermocouple?
Inspect the thermocouple regularly for heat stress, corrosion, or loose connections that can affect millivolt output. Keep the sensing tip clean from carbon buildup to ensure accurate flame detection. Ensure proper alignment with the pilot flame during installation. Replace the component if readings become unstable or ignition performance weakens.
-
What are common issues with the Hobart 14268 Thermocouple?
- Weak or inconsistent millivolt output causing shutdowns.
- Pilot flame not properly detected or intermittent sensing.
- Corrosion or heat damage reducing signal accuracy.
- Loose or faulty electrical connections.
- Carbon buildup on probe affecting performance and response time.