Dean 1896 Natural Gas Safety Control 3.5" WC Model 7000 BMVR

SKU: 1896 1-1896 Brand: Availability:
In Stock
(1)

$180.59 Price reduced from $278.25
Save $97.66


Have a Question? +1 (866) 863-0907

Specifications:

  • Nat Gas Safety, 3.5" Wc, Model 7000 Bmvr, Mfg#700-506
  • 3/4" Fpt In X 3/4" Fpt Out, Includes 3/4" X 1/2" Reducer
  • Bushings, Millivolt Actuator, Requires Wire Lead
  • Thermopile, 36" # 51-1121 Or 60" # 51-1257
  • 1/4" Cct Pilot Out, 300,000 Btu
  • For Lp Conversion Use # 51-1470
  • Bakers Pride Oven Following Models Made After 10/94:
  • Y600, Y800, Ds-805, Gs-805, D-125, 101, 151, 201
  • 251, 301, 351, 3151, 401, 451, 4151, Fc-(516,616,816)
  • Cecilware Fryer Fmp-30, Fmp-40, Fmp-65, Fmp-403, Fms-30,
  • Fms-40, Fms-65.
  • Frymaster Fryer Models Made Before Feb. 1993: Gf14, Gf40,
  • J1C, Jcfx, J3Fc, J65X, Mj15, Mj35, Mj235, Mjcf.
  • Imperial Fryer Series: If, Ihr, Ir.
  • Keating Fryer Gas Counter Units And Miraclean Griddles.

Description

The Dean 1896 Natural Gas Safety Control, Model 7000 BMVR is an effective gas pressure regulator which works accurately in natural gas systems. Working at 3.5” WC, it provides steady pressure output to appliances for proper functioning and safety. This design and safety features make it strong and safe from leakage of gas providing reliable protection in residential uses. This control improves energy conservation, minimizes operational hazards, and provides for the effective running of heating and gas-driven systems. Convenient in terms of installation and usage, it is a sound choice for achieving safe regulation of natural gas.

Dimensions:

  • Weight: 2.4 lbs
  • Length: 5.7 in
  • Height: 3.5 in
  • Width: 4.5 in

This Part Fits the Following Models

93 models
Dean 1212G Dean 1414G Dean 1414GDD Dean 1818G Dean 2020G Dean 714G Dean M30 Dean M35/M40 WITH UNDER FRYER FILTER MACHINE Dean M35GM Dean M40 Dean SM20G Dean TC-35 Atosa ATFS-40 Atosa ATFS-50 Atosa ATFS-75 Cecilware FMP403 Cecilware FMP40B Cecilware FMP40BSS Frymaster 35 Series Frymaster ESG35T Frymaster FM35 Frymaster FMCF Frymaster FMCFE Frymaster FMCFEC Frymaster FMP35 Frymaster FPP245 Frymaster GF14 Frymaster GF14-SD Frymaster GF40 Frymaster J1C Frymaster J3F Frymaster J65X Frymaster JCFX Frymaster KJ3FC Frymaster MJ35 Frymaster MJ40 Frymaster MJ45 Frymaster MJ50 Frymaster MJCF Frymaster MJCFE Frymaster MJCFEC Frymaster PMJ35 Frymaster PMJ45 Frymaster SM20 Frymaster SM220 Frymaster SM35G Frymaster SM40G Frymaster SM50G Frymaster SM60G Frymaster SM80G Frymaster SR162GN Frymaster SR38 Frymaster SR38G Frymaster SR42 Frymaster SR42G Frymaster SR52 Frymaster SR52G Frymaster SR62 Frymaster SR62G Frymaster Super Runner 52 Frymaster TC25 Garland 35-280 SERIES Garland 35-40 SERIES Garland 35-50 SERIES Imperial IF SERIES Imperial IF-25 Imperial IF-75 Imperial IF-BL SERIES Imperial IFS-25 Imperial IFS-40 Imperial IFS-40-OP Imperial IFS-50 Imperial IFS-50-OP Imperial IFS-75 Imperial IFS-75-OP Imperial IFSSP-250C Imperial IFSSP250C-12 Imperial IFSSP250C-125 Imperial IFST-25 Imperial IPC-14 Imperial IPC-18 Imperial IRF-40 Imperial IRF-50 Imperial IRFS-40 Imperial IRFS-50 Imperial ISSP250C Keating 14 Keating 14AA Keating AA SERIES Keating CM Market Forge DFFG Tri-Star TSF-4050HD Tri-Star TSF-6575-E-L
Showing of 93.0

Step1: Turn off gas supply and power to the fryer before starting work.

Step2: Allow equipment to cool completely for better handling.

Step3: Remove access panel to reach gas control assembly.

Step4: Disconnect inlet/outlet gas lines and pilot tubing.

Step5: Remove faulty safety control valve from mounting position.

Step6: Install new valve ensuring correct orientation.

Step7: Reconnect all lines tightly and check for leaks with approved solution.

Step8: Restore gas and test burner ignition for proper safety shutdown response.

  • What maintenance is required for the Dean 1896 Natural Gas Safety Control?

    Inspect the control regularly for secure gas connections and signs of damage or corrosion. Verify proper pressure regulation and response during operation checks. Clean surrounding components to prevent debris buildup. Ensure all safety cutoffs are tested periodically for accurate and better gas flow control.

  • What are common issues with the Dean 1896 Natural Gas Safety Control?

    • Inconsistent gas flow due to internal valve sticking or blockage.
    • Failure to maintain proper pressure regulation under load.
    • Ignition or startup delays caused by control malfunction.
    • Electrical or sensor failure leading to unsafe shutdown conditions.

Customer Reviews

5 Based on 1 reviews
5 ★
1
4 ★
0
3 ★
0
2 ★
0
1 ★
0
1 review
  • Consistent Gas
    Tune —

    Simple installation, ensures safe gas operation