Beverage Air 305-499D Refrigerator Drawer Gasket Gray Vinyl 8-3/8"X25-1/2"
Specifications:
| Attribute | Details |
|---|---|
| Width | 20" | 508 mm |
| Height | 4" | 102 mm |
| Depth | 4" | 102 mm |
Description
More Information:
- BEVERAGE AIR:305-176C ,305-499D ,BEV305-176C ,BEV305-499D
Step1: Turn off and unplug refrigerator to ensure safety.
Step2: Remove old gasket by loosening retaining screws or pulling from channel.
Step3: Clean door groove thoroughly to remove residue and ensure proper seal.
Step4: Align new gasket with door edge and press into channel evenly.
Step5: Secure screws if applicable and check full perimeter seal.
Step6: Close door and check no air gaps; adjust if needed.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Beverage Air 305-499D Evaporator Coil?
The Evaporator Coil should be kept free of dust, ice, and grease buildup. Check airflow through the coil and inspect for bent fins or early signs of refrigerant leaks.
-
How do I install the Beverage Air 305-499D Evaporator Coil?
- Disconnect power to the unit and recover the refrigerant following proper refrigeration procedures.
- Remove the evaporator cover and disconnect the fan assembly and temperature sensors.
- Detach the refrigerant line connections and mounting screws securing the old coil.
- Install the new evaporator coil in the same position and secure it with mounting hardware.
- Reconnect refrigerant lines, sensors, and fan assembly.
- Evacuate and recharge the system to the correct specifications.
- Restore power and verify proper frost pattern and airflow.
-
What are common issues with the Beverage Air 305-499D Evaporator Coil?
Common issues include refrigerant leaks at solder joints, ice buildup from restricted airflow, and inefficient cooling due to dirty fins. Blocked drains can also cause water overflow near the coil.
-
What are the operating limitations of the Beverage Air 305-499D Evaporator Coil?
Evaporator coils in this category typically operate in refrigeration ranges between 20°F–40°F coil temperature. They require adequate airflow and correct refrigerant charge to prevent icing and maintain efficiency.
-
What maintenance is required for the Beverage Air 305-499D Drawer Gasket?
Clean the gasket regularly to prevent debris buildup that may affect sealing performance. Inspect for cracks, deformation, or loss of elasticity. Ensure proper seating along the drawer edge to maintain consistent temperature retention during repeated operation.
-
What are the common issues with the Beverage Air 305-499D Drawer Gasket?
- Air leakage occurring.
- Gasket tearing or cracking.
- Poor drawer sealing.
- Loss of elasticity over time.
- Temperature retention reducing.