ROYAL RANGE 3232 Fryer NAT/LP Pilot 3-Way Flame 1/4" Tube

SKU: 3232 1-3232 Brand: Availability:
In Stock
(0)

$54.39 Price reduced from $70.64
Save $16.25


Have a Question? +1 (866) 863-0907

Specifications:

  • Nat/Lp Pilot, Factory # 6Ch14-10, 1830-491
  • Tube Size 1/4", Flame Pattern 3 Way, Hood Width 1-1/2"
  • Nat Orifice Pre-Installed # 26-1555, .018
  • Lp Orifice Included # 26-1554, .010
  • Cecilware Fryer Fmp 30, 40B, 403, 65, Fms 30, 54
  • Imperial Fryer Series: If, Ihr, Ir.
  • Vulcan Hart
  • Fryer Gf(91G,92G), Hf91G, Hf92G (Old 7891G & 7892G),Tk-35,
  • Series: 7400, 7500, 7800 (Depending On Date Of
  • Model). Series: Ef
  • 1Gr45M, 1Gr65M, 1Gr85M, 1Grc35, 1Grc45, 1Grc65, 1Grd45,
  • 1Grd65, 1Grs35, 1Grs45, 1Grs65, Ef3, Ef4, Ef5, Gr35, Gr35F,
  • Gr45, Gr45F, Gr65, Gr65F, Gr85, Gr85F, Grc35F, Grc45F,
  • Grc65F, Grc85F, Grd35F, Grd45F, Grd65F, Grd85F, Grs35F,
  • Grs45F, Grs65F, Grs85F

Description

The ROYAL RANGE 3232 Fryer Pilot 3-Way Flame 1/4" Tube is an essential assembly designed for use in commercial equipment operating with either natural gas or liquid propane systems. This component controls and directs to support a stable ignition and consistent burner operation within the unit. Installed as part of the system it distributes flow to maintain proper performance during cooking operations. It is commonly used in restaurant kitchens, food service stations and commercial kitchen conditions where stable heat control and continuous performance are required for food preparation requirements.

Dimensions:

  • Weight: 0.2 lbs
  • Length: 1.75 in
  • Height: 2.5 in
  • Width: 2 in

This Part Fits the Following Models

104 models
Royal Range RCF-25 Royal Range RFT-50 Royal Range RFT-60 Royal Range RFT-75 Cecilware FMP403 Cecilware FMP40B Cecilware FMP40BSS Imperial IF-25 Imperial IFS-25 Imperial IFS-40 Imperial IFSSP-250C Tri-Star TSF-4050HD Tri-Star TSF-6575-E-L Vulcan Hart 1GR35M Vulcan Hart 1GR45C Vulcan Hart 1GR45CF Vulcan Hart 1GR45D Vulcan Hart 1GR45DF Vulcan Hart 1GR45M Vulcan Hart 1GR65C Vulcan Hart 1GR65D Vulcan Hart 1GR65M Vulcan Hart 1GR85C Vulcan Hart 1GR85CF Vulcan Hart 1GR85D Vulcan Hart 1GR85DF Vulcan Hart 1GR85M Vulcan Hart 1GRC35 Vulcan Hart 1GRC45 Vulcan Hart 1GRC65 Vulcan Hart 1GRD35 Vulcan Hart 1GRD45 Vulcan Hart 1GRD465 Vulcan Hart 1GRD65 Vulcan Hart 1GRS35 Vulcan Hart 1GRS45 Vulcan Hart 1GRS65 Vulcan Hart 1GRS85 Vulcan Hart 1HG35M Vulcan Hart 1HG45C Vulcan Hart 1HG45D Vulcan Hart 1HG45M Vulcan Hart 1HG65C Vulcan Hart 1HG65D Vulcan Hart 1HG65M Vulcan Hart 1HG85C Vulcan Hart 1HG85D Vulcan Hart 1HG85M Vulcan Hart 2GR45MF Vulcan Hart 2GR65MF Vulcan Hart 2GR85MF Vulcan Hart 2GRS35 Vulcan Hart 2GRS85 Vulcan Hart 2HG45MF Vulcan Hart 2HG65MF Vulcan Hart 2HG85MF Vulcan Hart 3GR45MF Vulcan Hart 3GR65MF Vulcan Hart 3GR85MF Vulcan Hart 4GR45MF Vulcan Hart 7891E Vulcan Hart 7891G Vulcan Hart 7892E Vulcan Hart 7892G Vulcan Hart 7892G9 Vulcan Hart EF3 Vulcan Hart EF4 Vulcan Hart EF5 Vulcan Hart GHF91E Vulcan Hart GHF91G Vulcan Hart GHF92E Vulcan Hart GHF92G Vulcan Hart GR25 Vulcan Hart GR35 Vulcan Hart GR35F Vulcan Hart GR45 Vulcan Hart GR45F Vulcan Hart GR65 Vulcan Hart GR65F Vulcan Hart GR85 Vulcan Hart GR85F Vulcan Hart GRC35F Vulcan Hart GRC45F Vulcan Hart GRC65F Vulcan Hart GRC85F Vulcan Hart GRD35F Vulcan Hart GRD45F Vulcan Hart GRD65F Vulcan Hart GRD85F Vulcan Hart GRS35F Vulcan Hart GRS45F Vulcan Hart GRS65F Vulcan Hart GRS85F Vulcan Hart HF91E Vulcan Hart HF92E Vulcan Hart HF92G Vulcan Hart HG91G Vulcan Hart LG300 Vulcan Hart LG400 Vulcan Hart LG500 Vulcan Hart TK-35 Vulcan Hart TK45 Vulcan Hart TK45SS Vulcan Hart TK65
Showing of 104.0

A commercial-grade pilot burner assembly designed to support consistent ignition performance in gas fryer systems, this component ensures reliable flame stability for everyday kitchen operations. It is designed with a 3-way flame configuration that promotes uniform heat spread at the ignition point, ensuring smoother startup and stable burner operation. The integrated configuration is suitable for natural and liquid propane systems, making it a flexible replacement option across a wide range of fryer equipment used in professional kitchens. With a 1/4" tube connection and a compact hood width design of 1-1/2", this pilot assembly is engineered to deliver controlled flame output for dependable burner operation. It plays an important role in maintaining safe and efficient fryer performance, especially in systems where ignition irregularities or weak pilot flames can affect cooking consistency. Replacing a worn or clogged pilot assembly can help restore proper ignition response, reduce downtime, and support stable fryer operation in busy food service environments.

Equipment Compatibility:
For fryer ignition and pilot flame applications in commercial cooking systems, the ROYAL RANGE Pilot Burner 3232 is commonly used across a variety of gas fryer equipment setups. This Pilot Burner 3232 is compatible with commercial equipment from leading brands such as Cecilware, Imperial, Royal Range, Tri-Star, Vulcan Hart, and more, where stable pilot ignition and controlled flame performance are required for reliable operation.

Brand Compatibility:
This part replaces pilot burner components used in equipment from Cecilware, Grindmaster, Hobart, Imperial, Royal Range, Tri-Star, U-Line, Vulcan Hart, and more. Complete cross-reference details are provided separately for accurate identification.

Product Specifications:
Product Type: Fryer Pilot Burner Assembly
Manufacturer: Royal Range
SKU: 3232
Fuel Compatibility: Natural gas/propane
Connection: 1/4" tube
Flame Pattern: 3-way
Hood Width: 1-1/2"
Application: Commercial fryer ignition systems

Key Features:

  • 3-way flame design helps the fryer light up evenly and reliably.
  • Works with both natural gas and propane systems.
  • 1/4" tube connection gives a secure and steady gas flow.
  • Compact design helps keep the flame stable during use.
  • Helps fix weak or uneven pilot flames in fryers.
  • Improves safe and smooth fryer operation in busy kitchens.

“After replacing the pilot burner, the fryer lights up properly every time. The startup is much more reliable now.”

Step1: Turn off main gas supply and allow unit to cool.

Step2: Remove existing pilot carefully and inspect area.

Step3: Position new pilot in mounting bracket securely.

Step4: Connect gas line securely and ensure proper fit.

Step5: Tighten fittings and check alignment of flame ports.

Step6: Restore gas and test flame pattern at low setting.

  • What maintenance is required for the ROYAL RANGE 3232 Pilot?

    Inspect the pilot assembly regularly for carbon buildup or blockages and clean gently to maintain proper gas flow. Ensure secure tubing connections and verify flame stability during operation. Routine maintenance helps prevent ignition issues and supports efficient combustion. Always shut off gas before servicing.

  • What are common issues with the ROYAL RANGE 3232 Pilot?

    • Inconsistent or flickering flame.
    • Failure to ignite burner properly.
    • Gas pressure irregularities.
    • Loose or leaking tube connections.
    • Pilot flame extinguishing unexpectedly.
    • Carbon buildup affecting performance.

Customer Reviews

No reviews yet. Be the first to write one!

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More