Specifications:

Attribute Details
[Nat/Lp] [ 3/8"Fpt } [3/16" Cct Pilot In/Out ]
[ Safety ] [Width 2-1/2" ] [ Brand Baso Mfg# H15Hr-2 ]
[ 160,000 Btu ]
American Range, Duke, Imperial, Southbend
Garland Oven 44-40R, Gv28. Series G30A, G280, Gv280,
H280 Including H28(S).Hi28
Montague Oven Pizza 13P-1, 14P-1, 23P-2, 24P-2~
Bake/Roast 12B-1,12R-1, 13B-1, 13R-1,22C-2,23C-2~
Vectaire 115(A,S,X,Z).12R-1, 13B-1, 13R-1, 22C-2,23C-2
Us Range Grill Rgt-Bka-2436-1, Tb-24Gg.
Oven P-4-20, S-102626, Series P, Px, Sunfire < 9-5-00.
Series 836 Cuisine, Performer Ii & Pf.
Vulcan 7019A-1B

Description

The Garland CK253490-1 Range Safety Valve 3/8 in FPT X 3/16 in Tube controls the flow of gas to the burner by opening only when a pilot flame is detected to prevent the release of the gas in case of no ignition. It interacts with the thermocouple to provide regulated fuel flow to burners to provide safe burning. This is a safety valve that is fitted in the gas supply line of a commercial range, which is located between the pilot assembly and the burner manifold to control the flow of gas during cooking operations.

More Information:

  • AMERICAN RANGE:A80000||COMSTOCK CASTLE:17018||DUKE:213518||GARLAND:1415701 ,1415702 ,1415703 ,227071 ,253490-1 ,CK1415703 ,CK253490-1 ,CK253490-2 ,G01969-1 ,G01969-1H ,GL1415701 ,GL1415702 ,GL1415703 ,GLCK253490-2||IMPERIAL:2138-1||MONTAGUE:34604-7||SOUTHBEND:1173493

Step1: Turn off the range main gas supply.

Step2: Remove the old safety valve from the range.

Step3: Install the new valve in the same orientation.

Step4: Reconnect gas lines and check for leaks using a water solution.

Step5: Restore gas supply and test burner operation.

Step6: Keep hands and tools clear of open flames during testing.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Garland CK253490-1 Safety Valve?

    Inspect regularly for proper shut-off operation and check for any gas leaks. Clean connections and ensure tight fittings. Test safety mechanisms to confirm accuracy. Proper maintenance supports accurate gas control and secure range operation.

  • What are the common issues with the Garland CK253490-1 Safety Valve?

    • Failure to shut off the gas in unsafe conditions.
    • Gas leakage due to damaged seals.
    • Valve sticking or slow response.
    • Inconsistent gas delivery.
    • Blockages in gas pathways.
    • Corrosion is affecting valve integrity.