Randell ELMTR230 Refrigerator Fan Motor CW Rotation 3/16" x 7/8" Shaft 0.5A 120V
Specifications:
- Fan Motor, Cw From Shaft Side
- 120V, 3/16" X 7/8" Shaft, .5A, 1/2" Stack,
- 1-7/8" Mt Ctrs, Tabs On Bottom Sides.
- Fan Blade # 28-1295 ( Not Included)
- Delfield 186114-Buc, 186114-Ptb, 18648-Buc, 18648-Ptb,
- 18648Ptb, 18660-Buc, 18660-Ptb, 18672-Buc, 18672-Ptb,
- 18691-Buc, 18691-Ptb, 18699-Buc, 18699-Ptb, 18699Buc,
- 18699Ptb, 225L, 227L, 402, 403, 4048-St, 4048-Uc, 406,
- 406Cp, 407, 4148-St, 4148-Uc, 4427N, 4427N-6, 4427N-9M,
- 4432N, 4432N-12M, 4448N, 4448N-12, 4448N-18M, 4448N-8,
- 4460N, 4460N-12, 4460N-8, 4462N-18M, 4464N, 4464N-12,
- 4464N-12M, 4464N-16, 4464N-24M, 4464N-30M, 4464N-8, 4472N,
- 4472N-12, 4472N-18M, 4472N-24M, 4560N, 6025Xl-G,
- 6025Xl-Gh,7048-S, 9036, 9048, 9060, 9072, Ctb8146-Nb,
- Ctb8160-Nb,6025Xl-Ghr, 6025Xl-S, 6025Xl-Sh, 6025Xl-Shr,
Description
Dimensions:
- Weight: 1.1 lbs
- Length: 5 in
- Height: 4 in
- Width: 5 in
This Part Fits the Following Models
100 modelsDELFIELD:
2162691 2162691-S 2162691S 216291-S 216291S DEL2162691 DEL2162691-S DEL2162691S DEL216291-S DEL216291S
RANDELL:
EL MTR0230 ELMTR0230 ELMTR590 RDEL MTR0230 RDELMTR0230 RDELMTR230 RDELMTR590
Step1: Disconnect power supply and unplug refrigerator before opening access panel and ensure controls are off.
Step2: Remove rear panel, document wiring connections, and detach old motor carefully.
Step3: Install new motor onto bracket, ensuring correct CW orientation and secure fit.
Step4: Reconnect wiring per diagram and check tight connections for safety.
Step5: Restore power and test fan operation for smooth airflow and verify cooling performance.
-
What maintenance is required for the Randell ELMTR230 Fan Motor?
Clean Refrigerator fan blades and housing regularly to prevent dust buildup that reduces cooling efficiency. Inspect shaft wear, alignment, and lubrication to avoid vibration and motor strain. Ensure electrical connections are secure and follow voltage safety checks during operation.
-
What are common issues with the Randell ELMTR230 Fan Motor?
- Electrical failure from motor burnout or power surge.
- Reduced airflow caused by worn or damaged fan blades.
- Shaft misalignment leading to noise and vibration issues.
- Intermittent operation due to faulty wiring or connections.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More