Tri-Star 300188 Fryer Natural Gas Safety Control Valve 7000 BMVR 3.5" WC
Specifications:
| Attribute | Details |
|---|---|
| Nat Gas Safety, 3.5" Wc, Model 7000 Bmvr, Mfg#700-506 | |
| 3/4" Fpt In X 3/4" Fpt Out, Includes 3/4" X 1/2" Reducer | |
| Bushings, Millivolt Actuator, Requires Wire Lead | |
| Thermopile, 36" # 51-1121 Or 60" # 51-1257 | |
| 1/4" Cct Pilot Out, 300,000 Btu | |
| For Lp Conversion Use # 51-1470 | |
| Bakers Pride Oven Following Models Made After 10/94 | |
| Y600, Y800, Ds-805, Gs-805, D-125, 101, 151, 201 | |
| 251, 301, 351, 3151, 401, 451, 4151, Fc-(516,616,816) | |
| Cecilware Fryer Fmp-30, Fmp-40, Fmp-65, Fmp-403, Fms-30, | |
| Fms-40, Fms-65. | |
| Frymaster Fryer Models Made Before Feb. 1993 | Gf14, Gf40, |
| J1C, Jcfx, J3Fc, J65X, Mj15, Mj35, Mj235, Mjcf. | |
| Imperial Fryer Series | If, Ihr, Ir. |
| Keating Fryer Gas Counter Units And Miraclean Griddles. |
Description
More Information:
- ATOSA:301030003||BLOOMFIELD:DD-62193||CECILWARE:GML347A ,GML347F ,L347A ,L347F||DEAN:1896 ,807-0115 ,807-0306 ,807-2428 ,8070115 ,8070306 ,8072428 ,810-0014 ,8100014||ENTR?E:400042-1RS||FRYMASTER:1896 ,807-0115 ,807-0306 ,807-2428 ,807-3645 ,8070114 ,8070115 ,8070306 ,8072428 ,8073645 ,810-0014 ,8100014 ,FM1896 ,FM807-0115 ,FM807-0306 ,FM807-2428 ,FM8070114 ,FM8070115 ,FM8070306 ,FM8072428 ,FM810-0014 ,FM8100014||GARLAND:02511-1 ,1292799 ,2511 ,2511-1 ,F807-2425 ,F807-2428 ,F826-1580 ,GL1292799 ,GL2511||HOBART:00-348392-00001 ,00-353271-00001 ,110841-22 ,110841-23 ,348392-1 ,353271-1||IMPERIAL:1173 ,1173-RS ,1173RS ,IMP1173||JADE RANGE:8800000038||KEATING:2552 ,H00300H ,KEA2552 ,KEAH00300H ,P06066L||MARKET FORGE:93-0190||SOUTHBEND:1055997 ,1055999||STAR MFG:62193 ,DD-62193||TRI-STAR:300188 ,400042 ,AS-300188 ,TRS300188||U-LINE:343-701-400 ,343-811-400 ,700-506||VULCAN HART:110841-22 ,110841-23
Step1: Turn off gas fryer supply and disconnect power before servicing unit; ensure ventilation; verify compatibility.
Step2: Remove old valve and clean mounting area; inspect fittings and gas line.
Step3: Install new valve, align inlet/outlet, tighten fittings with proper sealant tape using approved method.
Step4: Reconnect lines, restore gas slowly, check for leaks with soap solution.
Step5: Test ignition and burner operation; ensure safety shutoff works and shutdown safety test.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Tri-Star 300188 Safety Control Valve?
Inspect the gas safety control regularly for secure wiring, clean electrical terminals, and proper millivolt response from the thermopile. Check for gas leaks and ensure stable pressure during operation. Keep the valve free from grease buildup and verify accurate ignition and shutoff during service checks.
-
What are common issues with the Tri-Star 300188 Safety Control Valve?
- Gas leakage due to worn seals.
- Inconsistent flame or burner shutdown due to valve blockage.
- Failure to open or close due to thermocouple malfunction.
- Reduced gas pressure affecting heating performance.