Garland 1019436 Oven Thermocouple 36" Long 20-30mV T-46

SKU: 1019436 1-1019436 Brand: Availability:
In Stock
(0)

$18.68 Price reduced from $24.25
Save $5.57


Have a Question? +1 (866) 863-0907

Specifications:

  • 1900 Series Heavy Duty Thermocouple 36" Long.20-30 Mv
  • Coaxial Thermocouple Threads = 11/32"-32
  • Anets Fryer 14Gs(U)
  • Garland Bake/Roast Deck Oven G2071, G2121, G2161, G2771
  • Market Forge
  • Steamer Where Applicable
  • Southbend Nodel?
  • Vulcan Hart Model?
  • Wolf Model F4-27

Description

The Garland 1019436 Oven Thermocouple 36" Long 20-30mV T-46 is the presence of a pilot flame and produces a millivolt signal when heated. The gas safety system receives that signal to permit the flow of gas when the correct flame conditions are observed. The thermocouple is connected to the gas valve by the lead and threaded connection to transmit the signal. It is a component that is placed close to the pilot burner assembly and its sensing tip is directly exposed to the flame in compatible Series equipment.

Dimensions:

  • Weight: 0.1 lbs
  • Length: 4.25 in
  • Height: 1 in
  • Width: 1 in

This Part Fits the Following Models

100 models
Garland G2071 Garland G2121 Garland G2161 Garland G2771 Anets MX-14E Blodgett CB24-140G Blodgett CB24-200G Blodgett CB-G Blodgett KLS-30 CROWN STEAM CB24-140G CROWN STEAM CB24-200G CROWN STEAM CB-G CROWN STEAM CG214 CROWN STEAM CG214E CROWN STEAM CG220 CROWN STEAM CG220E CROWN STEAM CG314 CROWN STEAM CG314E CROWN STEAM CG320 CROWN STEAM CG320E CROWN STEAM CG325 CROWN STEAM CG325E CROWN STEAM CG330 CROWN STEAM CG330E CROWN STEAM CG414 CROWN STEAM CG414E CROWN STEAM CQ-325S CROWN STEAM GC-2S CROWN STEAM GC-3S CROWN STEAM GDA-2S CROWN STEAM KLS-30 Vulcan Hart CONV OVEN Vulcan Hart E-30-C Vulcan Hart E-30-O Vulcan Hart E-40-C Vulcan Hart E-40-O Vulcan Hart FB18 Vulcan Hart FB24 Vulcan Hart FB361 Vulcan Hart FB362 Vulcan Hart FB363 Vulcan Hart FHB1 Vulcan Hart FHB1F Vulcan Hart FHBI1 Vulcan Hart FHBI1F Vulcan Hart FHBIO Vulcan Hart FHBIO1 Vulcan Hart FHBO Vulcan Hart FHBO1 Vulcan Hart FK361 Vulcan Hart FK362 Vulcan Hart FK363 Vulcan Hart FM12 Vulcan Hart FM18 Vulcan Hart FM361 Vulcan Hart FM362 Vulcan Hart FM363 Vulcan Hart FV361 Vulcan Hart FV362 Vulcan Hart FV363 Vulcan Hart G-30-C Vulcan Hart G-30-O Vulcan Hart G-40-C Vulcan Hart G-40-O Vulcan Hart HB1 Vulcan Hart HB1C Vulcan Hart HB1F Vulcan Hart HB1FC Vulcan Hart HB2 Vulcan Hart HBI1 Vulcan Hart HBI1C Vulcan Hart HBI1F Vulcan Hart HBI1FC Vulcan Hart HBI2 Vulcan Hart OVEN STD IGNIT Vulcan Hart STD OVEN Vulcan Hart TYG24C Vulcan Hart TYG36C Vulcan Hart TYG48C Vulcan Hart TYG60C Vulcan Hart TYG72C Vulcan Hart V1G12M Vulcan Hart V1G12S Vulcan Hart V1G24M Vulcan Hart V1G24S Vulcan Hart V212M Vulcan Hart V212S Vulcan Hart V218M Vulcan Hart V218S Vulcan Hart V2H36 Vulcan Hart V2H36C Vulcan Hart V2H36M Vulcan Hart V2H36S Vulcan Hart V3036 Vulcan Hart V3036C Vulcan Hart V3036M Vulcan Hart V3036S Vulcan Hart V3G36 Vulcan Hart V3G36C Vulcan Hart V3G36M
Showing of 100.0

Step1: Turn off electric supply and allow appliance to cool completely before starting to prevent burns or shock.

Step2: Remove access panel and disconnect old thermocouple from pilot assembly and control valve.

Step3: Install new thermocouple, securing tip in pilot flame area and tightening connection at valve.

Step4: Route lead carefully to avoid sharp bends or heat damage.

Step5: Reassemble panel, restore supply, and test pilot flame for stable reading.

  • What maintenance is required for the Garland 1019436 Thermocouple?

    Regularly inspect the thermocouple for soot buildup, corrosion, or loose connections that may affect flame sensing accuracy. Clean the probe gently with a soft cloth and ensure proper positioning near the pilot flame. Check wiring and mounting points during routine equipment servicing. Always disconnect gas and power supplies before handling the component for safe maintenance.

  • What are common issues with the Garland 1019436 Thermocouple?

    • Low millivolt output causing pilot to drop out.
    • Misalignment with pilot flame leading to weak heat detection.
    • Carbon deposits interfering with signal transfer.
    • Loose or worn connections causing intermittent operation.

Customer Reviews