Groen Z085153 Oven Ignition Control Module 24V F429 CA-145
Specifications:
| Attribute | Details |
|---|---|
| Ignition Control Module 24V, F429, Ca-145, # 441283 | |
| S8600H3002, | |
| 1 Mv, 2 Mv/Pv, 3 Pv, | |
| 4 Gnd(Burner), 5 24V(Gnd), 6 24V, 9 Spark, 90 Sec | |
| New/Style Black Box W/ Spark Connection On Top | |
| Groen Kettle, Marshall Air Broiler. | |
| For Vulcan Hart | |
| Nat/Lp Pilot, H501, # 51-1467 | |
| Ignition Cable, Vul419359 (Non-Stock) | |
| Vulcan Model 1Gr45M, 1Gr65M, 1Gr85M, 1Grc35, 1Grc45, | |
| 1Grc65,1Grd45, 1Grd65, 1Grs35, 1Grs45, 1Grs65, Ef3, Ef4, | |
| Ef5, G40Tb, Gr35,Gr35F, Gr45, Gr45F, Gr65, Gr65F, Gr85, | |
| Gr85F, Grc35F,Grc45F, Grc65F, Grc85F, Grd35F, Grd45F, | |
| Grd65F, Grd85F,Grs35F, Grs45F, Grs65F, Grs85F |
Description
More Information:
- ANETS:P8905-31||CLEVELAND:109967||GROEN:085153 ,144150 ,85153 ,GR085153 ,GR144150 ,GR85153 ,Z085153||HOBART:00-417980-00001 ,00-426225-00001 ,00-821078 ,00-857207-00001 ,417980-00001 ,417980-1 ,426225-00001 ,426225-1 ,821078 ,857207-00001 ,857207-1||LEGION:404007 ,LGN404007||MAGIKITCH'N:P8905-31||MARKET FORGE:501614||PITCO:P8905-31||SOUTHBEND:1174813||VULCAN HART:00-417980-00001 ,00-426225-00001 ,00-821078 ,00-857207-00001 ,417980-00001 ,417980-1 ,426225-00001 ,426225-1 ,821078 ,857207-00001 ,857207-1 ,VH857207-1
Step1: Disconnect power supply and shut off gas before servicing the oven.
Step2: Access the control compartment and locate the faulty ignition module.
Step3: Label and disconnect all wires from the old module.
Step4: Remove mounting screws and take out the module.
Step5: Position the new module and secure it with screws.
Step6: Reconnect wires to matching terminals.
Step7: Restore power and gas, then test ignition cycle safely.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
-
What maintenance is required for the Groen Z085153 Ignition Control Module?
Keep the control module area clean and free of grease, dust, and moisture to ensure accurate ignition. Inspect and tighten all wiring connections to prevent intermittent sparks. Confirm proper ventilation to avoid overheating. Always disconnect power before inspecting electrical components for safety.
-
How do I install the Groen Z085153 Ignition Control Module?
- Remove any panels to access the existing ignition control module.
- Disconnect wiring from the old module and remove it.
- Mount the Groen Z085153 in the same location, using original hardware.
- Reconnect wiring exactly as per original layout or wiring diagram.
- Restore power, then test the appliance for proper ignition and safe operation.
-
What are common issues with the Groen Z085153 Ignition Control Module?
- Ignition failure or damage spark during start-up.
- Intermittent operation due to loose or corroded wiring.
- Overheating from buildup of grease or low airflow.
- Faulty grounding causing inconsistent burner ignition.
-
Which models are compatible with the Groen Z085153 Ignition Control Module?
The Groen Z085153 Ignition Control Module is compatible with (among others) the Groen model (2)HY-5G.