Ranco K55-Q5606 Temperature Control Thermostat 3°F-15°F

SKU: K55-Q5606 Brand: Availability:
Out of Stock
(0)

$186.02 Price reduced from $262.74
Save $76.72


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
Thermostat
Turbo Air For Model Stgm35/48/50, Tgm-69/72Rs
Warm In 3F - Out -9.5F
Normal In -1F - Out -13F
Cold In -3F - Out -15F

Description

The Ranco K55-Q5606 Temperature Control Thermostat exists to control temperatures precisely in refrigeration systems Turbo Air models STGM35, STGM48, and TGM-72RS. This Temperature Control Thermostat functions in three modes including Warm In 3°F - Out -9.5°F and Normal In -1°F - Out -13°F and Cold In -3°F - Out -15°F to maintain suitable preservation environments for different products. The thermostat enhances both energy efficiency and operational cost reduction through improved performance and reduces maintenance requirements and system downtimes. The product stands out because of its sturdy build and straightforward setup process which makes it a necessary tool for organizations that need precise temperature control systems

More Information:

  • RANCO:K55-Q5606||TURBO AIR:30283D0700 ,30283K0100 ,30283K0110 ,30283M0710

Step1: Disconnect power supply and ensure the refrigeration unit is fully off.

Step2: Remove the old thermostat, labeling wires and noting capillary placement.

Step3: Install the new thermostat in the mounting bracket securely.

Step4: Route the sensing capillary to the original position without kinks.

Step5: Reconnect wiring to matching terminals as per configuration.

Step6: Restore power and test temperature cycling modes.

Step7: Damage insulated gloves and avoid damaging the capillary during handling.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Ranco K55-Q5606 Temperature Control Thermostat?

    Inspect wiring connections regularly to ensure they are secure and free from corrosion. Clean the thermostat housing and sensing components to prevent dust buildup. Verify calibration periodically to maintain accurate temperature control and avoid performance drift in refrigeration.

  • What are common issues with the Ranco K55-Q5606 Temperature Control Thermostat?

    • Inaccurate temperature readings due to calibration drift.
    • Compressor not engaging or shutting off incorrectly.
    • Faulty wiring causing intermittent operation.
    • Sensor failure leading to constant running or no response.
    • Temperature fluctuation outside set range.
    • Contact wear causing inconsistent switching.