Montague MONG11 Air Shutter Twin Plate 2 Slots

SKU: MONG11 1-MONG11 Brand: Availability:
In Stock
(0)

$8.74 Price reduced from $9.33
Save $0.59


Have a Question? +1 (866) 863-0907

Specifications:

  • Air Shutter, Twin Plate, 2 Slots, .463" Orifice Hole, Fits
  • 2.092" Dia Burner, W/ Locking Ears, 2-1/4"Od Air Shutter
  • For Cast Iron Burner.
  • Magikitch'N Charbroiler Series Dmc, Fm-Smb, Smb, Smb-Apm
  • Montague Broiler Ufc, Ufsc, Ufscc, Ufsmc (24 To 72, >10/91
  • Grill 2436, 2436T, 2472, 2472T, Grizzly G.
  • Range 136-5, 136-559~
  • Series:
  • Vulcan
  • Broiler Hcb1 (Old Cb-1L), Hcb2 (Old Cb-2L), Hcb44
  • (Old7844L), Hcbo40 (Old 7840Al), M7806, M7809, Series: Hgb.
  • Range 7830.
  • Wolf Oven

Description

The Montague MONG11 Air Shutter Twin Plate 2 Slots is used to control the flow of air by using two adjustable holes to provide controlled ventilation in enclosed areas. The slots may be separated to direct the flow in the required direction independently of each other, and balance the air distribution. This unit is designed to be mounted on the wall or ceiling and is flush with the surface provide the unit a streamlined look and blending well with existing duct work or ventilation systems. It has a twin-slot design that allows two air streams to be controlled simultaneously.

Dimensions:

  • Weight: 0.15 lbs
  • Length: 0.81 in
  • Height: 0.12 in
  • Width: 0.81 in

This Part Fits the Following Models

100 models
Montague 124-5 Montague 124-559 Montague 124-S Montague 12-5 Montague 12-559 Montague 12-559S Montague 12-5S Montague 12-8 Montague 12-9E Montague 12-9G Montague 12-S Montague 136-0E Montague 136-0EPL Montague 136-0G Montague 136-0GPL Montague 136-10E Montague 136-10G Montague 136-11 Montague 136-11E Montague 136-12 Montague 136-12E Montague 136-12EPL Montague 136-12PL Montague 136-13 Montague 136-13PL Montague 136-14 Montague 136-14E Montague 136-15 Montague 136-16 Montague 136-1E Montague 136-1G Montague 136-2E Montague 136-2G Montague 136-3E Montague 136-3G Montague 136-4E Montague 136-4G Montague 136-5 Montague 136-559 Montague 136-559S Montague 136-5A Montague 136-5S Montague 136-6 Montague 136-7 Montague 136-7PL Montague 136-8 Montague 136-8PL Montague 136-9A Montague 136-9ASE Montague 136-9E Montague 136-9G Montague 136LB Montague 136LB/12LB/UFLC-48R Montague 136LB/24LB/UFLC-60R Montague 136LB/UFLC-36R Montague 136S Montague 136XLB Montague 136XLB/UFLC-36R Montague 18-5A Montague 18-8 Montague 18-8PL Montague 18-9A Montague 18-9ASE Montague 18-S Montague 2/136LB/UFLC-72R Montague 2/C24-8 Montague 2/C24-8T Montague 2/C36-8 Montague 2/C36-8/C18-8 Montague 2/C36-8/C24-8 Montague 2/C36-8T Montague 2/C368T/C18-8T Montague 2/C368T/C24-8T Montague 2/V136/UFLC-7R Montague 236 Montague 236XLB Montague 24-5 Montague 24-559 Montague 24-559S Montague 24-5S Montague 24-8 Montague 24-8PL Montague 24-9E Montague 24-9G Montague 24-S Montague 336XLB Montague 36-0E Montague 36-0EPL Montague 36-0G Montague 36-0GPL Montague 36-10E Montague 36-10G Montague 36-11 Montague 36-11E Montague 36-12 Montague 36-12E Montague 36-12EPL Montague 36-12PL Montague 36-13 Montague 36-13PL
Showing of 100.0

ANETS:

-P9300-10 P9300-10

COMSTOCK CASTLE:

-16000 -25 16000 25

MAGIKITCH'N:

-30-05-00395 -30-05-00395-A -3005-0039500 -300500395 -300500395A

MONTAGUE:

-02038-9 -2038-9 -B-26 -B26 -G-11 -G11 -R-26 -R26 02038-9 2038-9 B-26 B26 G-11 G11 MON2038-9 MONB26 MONR26 R-26 R26

PITCO:

-P9300-10 P9300-10

SOUTHBEND:

-1127299 1127299

VULCAN HART:

-00-404060-00001 -00-719241 -104060-1 -19241 -404060-00001 -404060-1 -719241 00-404060-00001 00-719241 104060-1 19241 404060-00001 404060-1 6470 719241 806470 VH104060-1 VH404060-1 VH6470 VH806470

Step1: Turn off gas supply and allow burner to cool completely before servicing.

Step2: Remove existing air shutter assembly from burner tube using appropriate screwdriver.

Step3: Align new twin plate air shutter onto burner and secure mounting screws.

Step4: Set initial air gap for proper flame and ensure orifice alignment is unobstructed.

Step5: Restore gas, test ignition, and adjust air mix for stable blue flame.

  • What maintenance is required for the Montague MONG11 Burner Twin Plate Air Shutter?

    Clean the burner assembly regularly to remove grease, dust, and carbon deposits. Inspect the air shutter openings to ensure they are not obstructed. Check for proper alignment and secure all connections to maintain stable combustion. regular maintenance supports efficient burner performance and better operation.

  • What are common issues with the Montague MONG11 Burner Twin Plate Air Shutter?

    • Inconsistent flame caused by dirty burner ports.
    • Delayed ignition from clogged orifice opening.
    • Excess soot due to incorrect air-to-gas ratio.
    • Reduced heating efficiency from air shutter blockage.

Customer Reviews

No reviews yet. Be the first to write one!

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More