Lang 30200-12 Convection Oven Motor

SKU: 30200-12 Brand: Availability:
In Stock
(0)

$1,004.88 Price reduced from $1,991.44
Save $986.56


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
1/3 Hp, 115/230V, 5.2-6.2 Amp, 50/60 Hz, 1 Ph, 1725 RPM,
4" X 1/2" Shaft, N48Y Frame, 5-3/4" X 3-1/2" Mtg. Plate
Lang Blower Wheel, # 26-3467 (8-1/2" Dia)
Lang Oven Eco,Gco,Ehs Blower Wheel # 26-2931 ( 10 3/4"Dia)
Lang/Star Oven Ecco-A, Ecco-C (With S/N Up To G71021, Prefix
X~
Mrs Fields With S/N X85095 To X90435), Ecco-C5S,
Ecco-C5S-Cs (Mrs Fields & Schlotskys), Ecco-Lmbr
(Cinnabon With S/N Prefix X), Ecco-S, Ecco-Sii (With
S/N E67664 To F90435), Ecco-T (Before S/N F90435),
Ehs-C (Including Braums), Ehs-(C-Lmbr,C1-1208Bk,
Cir,Cir-Bk), Ehs-S (Including Tcby), Ehs-T, F-11S
(With S/N A22107 To A22196 & Beg W/A23030), F-11Sm,
Gpo, Ppp-(1,2,3). Series F-6.
Range Rf21S, Rf21S-(M,Xlh), Rf42S, Rf42S-(M,Xlh), Scr-30,
Tcr-30.

Description

The Lang 30200-12 Convection Motor is used in different models of ovens including those from Lang, Star, and Mrs. Fields. It has a 1/3 HP motor with 4” x ½” shaft and 5 ¾” x 3 ½” mounting plate. It has a motor that runs on 115/230V, 5.2-6.2 AMP, and 1725 RPM for steady airflow and heat circulation. It is compatible with many models such as ECO, GCO, EHS, and others. The motor drives the blower wheel to enhance the cooking efficiency to ensure that the food cooks evenly.

More Information:

Step1: Turn off power supply and unplug oven to avoid electrical shock.

Step2: Remove rear or side access panel using proper tools.

Step3: Disconnect motor wiring, noting connections.

Step4: Remove mounting bolts and take out old motor.

Step5: Install new motor and secure with bolts.

Step6: Reconnect wiring as labeled.

Step7: Replace panel, restore power, and test operation.

Step8: Ensure all connections are tight and check motor rotation direction before full use.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Lang 30200-12 Motor?

    Maintain the Lang Convection Oven Motor by regularly cleaning dust and grease buildup from the housing and ensuring proper ventilation. Check electrical connections for tightness and signs of wear. Lubricate bearings if specified. Routine inspection prevents overheating and performance issues.

  • What are common issues with the Lang 30200-12 Motor?

    • Convection Oven overheating due to blocked airflow or heavy usage.
    • Motor not starting because of electrical failure or capacitor issues.
    • Unusual noise or vibration from worn bearings or misalignment.
    • Inconsistent speed affecting oven performance.