Attribute Details
[Nat/Lp ] [ 3/8" Fpt] [ Safety ] [ 1/8" Fpt Pilot In/Out ]
[ Width 2-1/2" ] [ 163,000 Btu ][ Brand Baso ]
[ Mfg# H15Ar-3 ]
Vulcan/Wolf
Oven Ch & Chss (From 1980-89) Gh, F, Fs.
New Style Has Thermocouple Inlet 90 Degrees To Gas In/Out.
Product Change Baso Has Changed This Valve.
They Turned The Thermocouple Hole 90 Deg.
It Now Is On The Right Side When Facing The Gas Inlet.
- Not On The End.

Description

The Vulcan Hart 00-705025-0000A Pilot Safety Valve Kit 3/8" operates by regulating the supply of gas to the pilot assembly of the oven, so that gas supply is limited to when the pilot flame is on. It works by a built-in system that detects the heat of the pilot flame, and will automatically turn off the gas supply in the event of the flame being extinguished. This kit is normally fitted in the gas line system of commercial or industrial ovens, between the main gas supply and the pilot assembly to control the flow of the gas and ensure that things run well.

More Information:

  • HOBART:00-497765-00001 ,00-705025-0000A ,00-720719-00001 ,15003 ,20719 ,497765-00001 ,497765-1 ,5025-A ,5025A ,705025-0000A ,705025-A ,715003 ,720719-00001 ,720719-1||JOHNSON CONTROLS:H15AR-3C||VULCAN HART:00-497765-00001 ,00-705025-0000A ,00-720719-00001 ,00-962067-00001 ,15003 ,20719 ,497765-00001 ,497765-1 ,5025-A ,5025A ,705025-0000A ,705025-A ,705025A ,715003 ,720719 ,720719-00001 ,720719-1 ,962067-00001 ,962067-1 ,VH20719 ,VH497765-1 ,VH5025-A ,VH5025A ,VH705025-A ,VH705025A ,VH715003 ,VH720719

Step1: Turn off gas and power, shut off main gas supply and allow oven to cool completely.

Step2: Remove the access panel and disconnect the old safety valve.

Step3: Note gas line routing for reassembly.

Step4: Install a new valve, ensuring correct alignment.

Step5: Tighten fittings securely and check for leaks using soapy solution or a leak detector.

Step6: Restore power and test pilot ignition.

Step7: Verify proper flame and safe operation.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Vulcan Hart 00-705025-0000A Pilot Safety Valve Kit?

    Inspect the safety valve for gas leaks, wear, and debris buildup. Clean surrounding pilot assembly and ensure secure the connections. Regular servicing maintains ignition accuracy, prevents gas flow issues, and ensures better oven operation.

  • What are common issues with the Vulcan Hart 00-705025-0000A Pilot Safety Valve Kit?

    • Gas leakage from worn seals or fittings.
    • Weak or intermittent pilot flame.
    • Valve sticking causing delayed ignition.
    • Clogged pilot passage reducing gas flow.
    • Failure to maintain steady oven temperature.