Imperial 30030 Thermocouple 18"

SKU: 30030 1-30030 Brand: Availability:
In Stock
(0)

$18.28 Price reduced from $23.75
Save $5.47


Have a Question? +1 (866) 863-0907

Specifications:

  • 1980 Series Snap Fit 18" Thermocouple, 20-30 Mv
  • American Permanent Ware Griddle Ggm, Ggt
  • Comstock Castle Oven Bake, Barbeque & Pizza Ovens.
  • Series: C, D, F, K.
  • Dynamic Cooking Systems Oven All
  • Garland Broiler 6-40/50S, 7-40/50S, 8-40/50S, 60-40/50R
  • Oven Series: H281, P280. Standard Oven From 03/99 In
  • Canada Only, Range: G20-Sph
  • Imperial Model?
  • Star Fryer M14, Mi4 (D,Dl), M18, Mi8(D,Dl), M43, 215B, 216,
  • 403 404
  • Us Range Oven P-4-20.
  • Wolf Oven Ch, Chssd, R

Description

The Imperial 30030 Thermocouple 18" is a flame sensor that is used in gas-powered commercial cooking systems. It is installed by the pilot assembly and detects heat and then produces a millivolt signal to hold the gas valve open as long as it is operating. In case of flame, the signal is terminated and the flow of the gas is turned off to avoid unsafe conditions. This thermocouple is widely applicable in ranges and broilers available in kitchens. The system is in the safety and ignition system of the appliance that aids in maintaining the same flame control and equipment.

Dimensions:

  • Weight: 0.1 lbs
  • Length: 5 in
  • Height: 0.5 in
  • Width: 4 in

This Part Fits the Following Models

100 models
Imperial IR-2000-24 Imperial IR-2000-36 Imperial IR-2000-48 Imperial IR-2000-60 Imperial IR-2000-72 Imperial IR-36-DS Imperial IR-4-G12 Imperial IR-4-S18 Imperial IR-6 American Range AR American Range AR SERIES American Range AR-30 American Range ARB American Range AR-C American Range ARDS American Range ARG American Range ARLB American Range ARLM-1 American Range ARLM-2 American Range AR-NV American Range ARRG American Range ARTL1-C American Range ARTL1-NV American Range ARTL2-C American Range ARTL2-NV American Range ARTL3-C American Range ARTL3-NV American Range ARW-36 Cecilware FM-28A Cecilware GF-16A Cecilware GF-28A Comstock Castle F-SERIES Garland 40 Garland 40/50 SERIES Garland 50R Garland 50S Garland BCO SERIES Garland ECO SERIES Garland ECO-G-10 Garland G20-SPH Garland G280 SERIES Garland G286 Garland G30A SERIES Garland GV280 SERIES Garland H/P-280 Garland H280 Garland H280 SERIES Garland H283 Garland H284 Garland H285 Garland H286 Garland H287 Garland H288 Garland H289 Garland HP-280 SERIES Garland ICO SERIES Garland ICO-G-10-M Garland MSA36 Garland S-10 Garland S-10-26 Garland S-10-2626 Garland S-10-2626CP Garland S-10-26CP Garland S-10-26CP26CP Garland S-24BG-2626CP Garland S-4 Garland S-4-20 Garland S-6 Garland S-6-24BG-26 Garland S-6-24BG-2626 Garland S-6-24BG-2626CP Garland S-6-24BG-26CP Garland S-6-24BG-26CP26CP Garland S-6-26 Garland S-6-26CP Garland SX-10-26 Garland SX-10-2626 Garland SX-1HT-4 Garland SX-1HT-4-26 Garland SX-24G-2 Garland SX-24G-2-26 Garland SX-24G-6-26 Garland SX-24G-6-2626 Garland SX-4 Garland SX-4-20 Garland SX-6 Garland SX-6-24BG-26 Garland SX-6-24BG-2626 Garland SX-6-26 Garland TG3 Garland TG3 SERIES Garland TG3CH Garland TG4 Garland TG4 SERIES Garland TG4CH Jade Range JBR-6-36C Jade Range JSR SERIES Jade Range JSR-6-36C Jade Range JSR-8-36C Jade Range JTRH-4-36C
Showing of 100.0

AMERICAN RANGE:

10485 A11100 AMRA11100

ANETS:

ANEP8900-32 P8900-32

APW WYOTT:

1473103 AS-1473103

CECILWARE:

F002A F002F GMF002A GMF002F

COMSTOCK CASTLE:

17005 COM17005 COMT46 T46

DYNAMIC COOKING SYSTEMS:

13007 13007-01

IMPERIAL:

1121 IMP1121

ROYAL RANGE:

2175 2179

STAR MFG:

2J-6726 2J6726 6726 H456

STERO:

STA2J-6726 STA2J6726 STA6726 STAH456

TRI-STAR:

310210 TRS310210

U-LINE:

1980-018

Step1: Turn off gas and power, cool appliance.

Step2: Remove access panel and disconnect old thermocouple from valve and pilot.

Step3: Route new thermocouple ensuring tip sits in pilot flame correctly.

Step4: Secure connection to gas valve and tighten mounting hardware.

Step5: Restore gas, ignite pilot, check stable flame and safety shutdown.

  • What maintenance is required for the Imperial 30030 Thermocouple?

    Check the thermocouple periodically for dirt, corrosion, or loose fittings that may affect performance. Clean the tip carefully to maintain proper flame sensing. Ensure it is correctly positioned in the pilot flame. Always turn off the gas supply before performing maintenance operation.

  • What are common issues with the Imperial 30030 Thermocouple?

    • Weak or inconsistent millivolt signal output.
    • Improper alignment with pilot flame.
    • Loose or damaged connection threads.
    • Heat damage or residue buildup on the sensor.

Customer Reviews

No reviews yet. Be the first to write one!

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More