Frymaster 8101569 1/4 Ton Expansion Valve

SKU: 8101569 1-8101569 Brand: Availability:
In Stock
(0)

$101.18 Price reduced from $214.37
Save $113.19


Have a Question? +1 (866) 863-0907

Specifications:

  • Drain Valve W/Lock, 1 1/4" Fpt
  • Frymaster Fryer Biph14, Biph252/255, Biph352/355,
  • Biph452/455, Biph52/55, Biph552, Bire14, Fh150, Fm35, Fm45,
  • Fm47, Fmh50, Fph150, Fph17, Fph50, Fpph355-Sc, Fpph355Csd,
  • Fpph455-Sc, Gf14, Gf14-Sd, Gf40, H14, H14 Naval, H14 Sub,
  • H17, H17 Naval, H20.5, H22, H22 Naval, H50, H55, Mh52,
  • Mj35,Mj45, Mj47, Mjh150, Mjh50, Mph14, Mph152/155,
  • Mph252/255,Mph352/355, Mph452/455, Mph52/55, Mre14, Navy
  • Submarine,Ph155Csd, Pmj35, Pro Series, Re14, Re17, Re22,
  • Wfp347Ecse

Description

The Frymaster 8101569 Drain Valve with Handled 1.25 is a spare part that fits in commercial fryers. It provides a regulated vent to empty cooking oil or any other liquid in the fryer basin and the handle is provided as well, enabling easy and safe use. The valve is installed at the bottom of the fryer, and it is operational with the oil management system of the appliance to be used for draining to the valve with minimum spillage. To maintain the usual operation of the drain valve, it is significant to maintain the drain valve.

Dimensions:

  • Weight: 2.1 lbs
  • Length: 7.25 in
  • Height: 3.38 in
  • Width: 2.25 in

This Part Fits the Following Models

126 models
Frymaster 35 Series Frymaster BIH SERIES Frymaster BIMH52 Frymaster BIPH Frymaster BIPH14 Frymaster BIPH252/255 Frymaster BIPH352/355 Frymaster BIPH452/455 Frymaster BIPH52/55 Frymaster BIPH552 Frymaster BIRE14 Frymaster BK255C Frymaster BK255RC Frymaster BK355C Frymaster BK355RC Frymaster BK414TRC Frymaster BKFP214TC Frymaster BKFP214TRC Frymaster BKFP217C Frymaster BKFPx55xx Frymaster BKH55 Frymaster FH150 Frymaster FM345E Frymaster FM35 Frymaster FM45 Frymaster FM47 Frymaster FMH50 Frymaster FMP35 Frymaster FMPH455 Frymaster FP247 Frymaster FP247-2L Frymaster FP247-2R Frymaster FP247-4 Frymaster FP347 Frymaster FP347-2L Frymaster FP347-2R Frymaster FP347-4L Frymaster FP347-4R Frymaster FP347-6 Frymaster FP447 Frymaster FPEL214CA Frymaster FPEL314CA Frymaster FPEL414CA Frymaster FPGL230CA Frymaster FPGL330C Frymaster FPGL330CA Frymaster FPGL430CA Frymaster FPGL430CASC Frymaster FPH SERIES Frymaster FPH150 Frymaster FPH155 Frymaster FPH17 Frymaster FPH17SC Frymaster FPH350C-SC Frymaster FPH350CSD Frymaster FPH450C Frymaster FPH50 Frymaster FPH50C-SC Frymaster FPP245 Frymaster FPPH-14 Frymaster FPPH-17 Frymaster FPPH-22 Frymaster FPPH355BLCSD Frymaster FPPH355CSD Frymaster FPPH355-SC Frymaster FPPH417TC Frymaster FPPH455-SC Frymaster FPRE14 Frymaster FPRE17 Frymaster FPRE217/222 Frymaster FPRE317 Frymaster GF14 Frymaster GF14-SD Frymaster GF40 Frymaster H14 Frymaster H14 Naval Frymaster H14 SERIES Frymaster H14 Sub Frymaster H14SC Frymaster H17 Frymaster H17 Naval Frymaster H17 SERIES Frymaster H17SC Frymaster H20.5 Frymaster H22 Frymaster H22 Naval Frymaster H22 SERIES Frymaster H22SC Frymaster H50 Frymaster H55 Frymaster MH SERIES Frymaster MH52 Frymaster MJ SERIES Frymaster MJ147-2 Frymaster MJ247 Frymaster MJ347 Frymaster MJ35 Frymaster MJ40 Frymaster MJ447 Frymaster MJ45 Frymaster MJ47 Frymaster MJ50 Frymaster MJH SERIES Frymaster MJH150 Frymaster MJH50 Frymaster MPH14 Frymaster MPH152/155 Frymaster MPH252/255 Frymaster MPH352/355 Frymaster MPH452/455 Frymaster MPH52/55 Frymaster MRE14 Frymaster NAVY SUBMARINE Frymaster OCF30 Electric Series Frymaster OCF30 Gas Series Frymaster OCF30ATOE Frymaster OCF30ATOG Frymaster PH155CSD Frymaster PMJ145-SD Frymaster PMJ35 Frymaster PMJ45 Frymaster PRO SERIES Frymaster RE14 Frymaster RE17 Frymaster RE22 Frymaster WFP347ECSE
Showing of 126.0

Step1: Turn off power and refrigerant supply to the unit for safety.

Step2: Remove the old expansion valve by disconnecting refrigerant lines.

Step3: Clean the connection points to ensure a proper seal.

Step4: Install the new valve, reconnecting all lines securely.

Step5: Restore refrigerant and power, then test the system for correct cooling operation.

  • What maintenance is required for the Frymaster 8101569 Expansion Valve?

    Regularly inspect the valve for leaks, dirt, or corrosion. Ensure connections are tight and free from obstructions. Proper maintenance maintains efficient refrigerant flow, prevents system pressure issues, and ensures safe operation.

  • What are common issues with the Frymaster 8101569 Expansion Valve?

    • Refrigerant leaks.
    • Reduced or uneven refrigerant flow.
    • Erratic temperature control.
    • Valve sticking or failing to open properly.