Vulcan Hart VH921565 24" Thermocouple

SKU: VH921565 Brand: Availability:
In Stock
(0)

$19.25 Price reduced from $25.00
Save $5.75


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
1980 Series Snap Fit 24" Thermocouple, 20-30 Mv
Coaxial Thermocouple Threads = 11/32"-32
Anets Grill Ss2436.
Dean Fryer Where Applicable
Dynamic Cooking Systems Oven Where Applicable.
Garland Broiler Model?

Description

The Vulcan Hart VH921565 Thermocouple 24" is a component of a system that is installed in compatible commercial cooking equipment to monitor and relay temperature data to the control system. It operates by detecting the heat at the burner or oven section, and relaying the information to control the fuel supply and keep the operation constant. This is a thermocouple fitted in the cooking chamber or burner assembly as part of the safety and control system. In a commercial kitchen, its use assists in proper temperature control.

More Information:

  • ANETS:P8900-47||DEAN:1149 ,807-3550 ,8073550||DUKE:213590||DYNAMIC COOKING SYSTEMS:13007-3||FRYMASTER:1149 ,807-3550 ,8073550 ,FM1149 ,FM807-3550 ,FM8073550||GARLAND:4102920 ,G01754-24||JADE RANGE:4619900000||KEATING:4485 ,KEA4485 ,KEAP15239L ,P15239L||METAL MASTERS:310211||PITCO:P8900-47||SOUTHBEND:1173576 ,1182580 ,P8900-47||STAR MFG:2J-Z4609 ,Z4609||STERO:STA2J-Z4609 ,STAZ4609||VULCAN HART:112788-1 ,20040 ,412788-1 ,920040 ,921565 ,VH112788-1 ,VH20040 ,VH412788-1 ,VH920040 ,VH921565

Step1: Turn off gas and electrical power and allow appliance to cool completely.

Step2: Remove access panel and disconnect old thermocouple carefully.

Step3: Align new thermocouple into mounting bracket until secure.

Step4: Reconnect lead to control valve ensuring tight connection.

Step5: Restore power and test ignition for proper millivolt signal.

Step6: Check flame safety shutdown and secure panel properly.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Vulcan Hart VH921565 Thermocouple?

    Keep the thermocouple clean and free from soot or grease buildup to maintain accurate flame sensing. Inspect for oxidation, cracks, or wear on the probe. Ensure it is correctly aligned in the pilot flame and verify wiring integrity regularly.

  • What are common issues with the Vulcan Hart VH921565 Thermocouple?

    • Pilot flame not being detected.
    • Weak or unstable signal output.
    • Oxidized or worn sensing tip.
    • Loose electrical connections.
    • Frequent burner shutdowns.