Sporlan Y1001-FBR-1/4-Z Refrigerator 1/4 Ton Expansion Valve
Specifications:
- 1/4 Ton, Delfield 18648-Pdl, 18648-Ptl, 18672-Pdl,
- 18672-Ptl, 18699-Ptl, 8100-Ef, 8100-Efn, 8118-Ef, 8132-Ef,
- 8145-Ef, 8148-Efn, 8159-Ef, 8169-Efn, 8172-Ef, 8186-Ef,
- 8191-Efn, Cm-2, Cmb-2, Cp-2, Cp-4, Cpb-2, Cpb-4, Dc-Ft2,
- Dc-Ft3, Dc-Ft4, Dc-Ft5, Dc-Ft6, Dc-L2, Dc-L3, Dc-L4, Dc-L5,
- Dc-L6, Dc-Mc2, Dc-Mc3, Dc-Mc4, Dc-Mc5, Dc-Mc6, Dch-Bs-27L,
- Dch-Bs-27R, Dch-Bs-58L, Dch-Bsn-32L, Dch-Bsn-32R,
- Dch-Dc-27L, Dch-Dc-27R, Dch-Ec-68R, Dch-Fs-48L, Dch-Fsn-33L,
- Dch-Fsn-33R, Dch-Fsn-Drw, Dch-Rb-45-38, Dch-Rb-45-40,
- Dch-Sc-55R, Dch-Scs-33L, Dch-Scs-33R, Dch-Sn-55R,
- Dch-Tf-55L, Dch-Tf-55R, Dch-Ucr-27R, Dch-Ucr-75L,
- Dch-Ucr-75R, F13Bc44, F13Bc56, F13Bc72, F13Br36, F13Br48,
- F13Br60, F13Wc32, F13Wc44, F13Wc56, F13Wc68, F13Wr24,
- F13Wr36, F13Wr48, F13Wr60, F18Dc52, F18Dc60, F18Dc68,
- F18Dc82, F18Dc91, F18Dc99, F18Dr44, F18Dr52, F18Dr60,
Description
Dimensions:
- Weight: 0.95 lbs
- Length: 5 in
- Height: 3 in
- Width: 5 in
This Part Fits the Following Models
373 modelsDELFIELD:
SPORLAN:
Y1001-FBR-1/4-Z
Step1: Isolate power, recover refrigerant, and depressurize system safely before starting.
Step2: Remove old expansion valve, noting orientation and capillary connections.
Step3: Install new valve ensuring correct inlet and outlet alignment.
Step4: Braze joints using purge to prevent oxidation and overheating.
Step5: Vacuum system thoroughly and perform leak test before charging refrigerant.
Step6: Set superheat, restore refrigerant charge, and monitor system operation for stability.
-
What maintenance is required for the Sporlan Y1001-FBR-1/4-Z Expansion Valve?
Inspect the expansion valve periodically for refrigerant leaks, corrosion, or damaged sensing components. Verify that connections remain secure and that the valve responds properly to system load changes. Keep the refrigeration system clean and free of contaminants that could restrict refrigerant flow. Always recover refrigerant and disconnect power before servicing refrigeration components.
-
What are common issues with the Sporlan Y1001-FBR-1/4-Z Expansion Valve?
- Clogging in valve or orifice causing restricted refrigerant flow.
- Refrigerant leakage at joints or seals.
- Valve sticking leading to improper superheat control.
- Erratic cooling performance or fluctuating evaporator pressure.
- Sensor misreading causing unstable regulation.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More