Sporlan Y1260-LAC-4-225 Head Pressure Control Valve

SKU: Y1260-LAC-4-225 Brand: Availability:
In Stock
(0)

$287.40 Price reduced from $353.94
Save $66.54


Have a Question? +1 (866) 863-0907 / (630) 326-8602

Specifications:

Attribute Details
Head Pressure Control Valve
Manitowoc Bd1003W, Bd1092N, Bd1302A, Bd1303W, Bd1392N,
Bd1802A, Bd1803W, Bd1892N, Br0450A, Br0451W, Br0490N,
Br0601W, Br0690N, Br0800A, Br0801W, Br0890N, Br1000A,
Br1090N, Br1300A, Br1301W, Br1390N, Br1800A, Br1801W,
Br1890N, By0604A, By0605W, By0694N, By0805W, By0894N,
By1004A, By1005W, By1094N, By1304A, By1305W, By1394N,
By1804A, By1805W, Cvd0675, Cvd0685, Cvd675, Cvd685,
Ib0622Dc, Ib0624Yc, Ib0682Dc, Ib0684Yc, Ib0694Yc, Ib0696Yc,
Id0502A, Id0503W, Id1402A, Id1403W, Iy0504A, Iy0505W,
Iy1404A, Iy1405W, Iyp0504A, Jc0495, Jc0895, Jc1395, Jd0452A,
Jd0453W, Jd0492N, Jd0802A, Jd1802A, Jd1803W, Jd1892N,
Jr0451W, Jr0490N, Jr0600A, Jr0601W, Jr0690N, Jr0800A,
Jr0801W, Jr0890N, Jr1000A, Jr1001W, Jr1090N, Jr1300A,
Jr1301W, Jr1390N, Jr1800A, Jr1801W, Jr1890N, Jy0454A,

Description

The Sporlan Y1260-LAC-4-225 Head Pressure Control Valve is a part of a system for use with compatible commercial equipment. The valve is mounted in the refrigerant circuit to control the flow in the circuit under different operating conditions, and the head pressure. It aids in maintaining stable system performance in low ambient temperatures and proper condenser pressure for refrigeration operation. This part is an element in enhancing the efficiency of cooling systems and compressor performance. It is widely used in refrigeration and systems, and is occurs, when pressure regulation is not consistent for the system's operation.

More Information:

  • MANITOWOC:4070 ,83-6809-3 ,8368093 ,MAN8368093||SPORLAN:Y1260-LAC-4-225

Step1: Shut off power, isolate electrical supply, and recover refrigerant safely.

Step2: Verify flow arrow and mount valve on discharge line securely ensure proper alignment.

Step3: Braze connections using heat sink and wet cloth; avoid overheating valve body.

Step4: Connect sensing line to receiver or condenser outlet as specified per manufacturer specs.

Step5: Pressure test, evacuate system, then charge and verify setpoint operation and pressure settings.

Customer Reviews

No reviews yet. Be the first to write one!

  • What maintenance is required for the Sporlan Y1260-LAC-4-225 Head Pressure Control Valve?

    Keep the valve clean and ensure refrigerant lines are free from oil, moisture, and debris that can affect regulation. Inspect periodically for stable head pressure performance and proper system response under varying ambient conditions. Routine system checks assist in maintaining efficient operation and preventing internal sticking or blockage.

  • What are common issues with the Sporlan Y1260-LAC-4-225 Head Pressure Control Valve?

    • Incorrect head pressure regulation is causing weak system efficiency.
    • Valve sticking due to contamination or debris buildup.
    • Fluctuating or unstable system pressure control.
    • Restricted flow through partially blocked internal components.
    • Sensing or control response delays.
    • Mechanical wear affecting pressure modulation accuracy.