American Range 10436 Adjustment Pilot Valve 1/8" MPT X 3/16" CCT

SKU: 10436 1-10436 Brand: Availability:
In Stock
(0)

$7.52


Have a Question? +1 (866) 863-0907

Specifications:

  • Pilot Adjustment Valve
  • [ 1/8" Mpt X 3/16" Cct ] ] [Width 1-1/8"],
  • Straight, Adjustable
  • American Range
  • Bakers Pride Broiler Ch10. Series: 50, Gg, Xx.
  • Dynamic Cooking Systems Broiler Cheesemelter, Salamander.
  • Garland Oven 60/40R, Stw286 & Where Applicable.
  • Griddle Series: Gd
  • Imperial Broiler Eba-3223. Series: Gd, Icb, Icma, Isb, Msq.
  • Grill Series: Imga, Itg.
  • Range Series: Icra, Isp-J, Ispa.
  • Wolf Broiler Cmss Cheesemelter, Fshb & Hbss
  • (Old F & Fs-855), Scb.
  • Grill Gg, Stg.

Description

The American Range 10436 Adjustment Pilot Valve 1/8"MPT X 3/16" CCT adjusts the gas flow to the pilot assembly by adjusting pressure using a variable inner mechanism. It permits the initial flame to be fine-tuned by adjusting the amount of volume of gas flowing through the inlet and outlet connections. It is actually fitted in the gas control system, usually between the line of gas supply and the ignition burner. This is applied in commercial cooking appliances to aid in consistent operations in the pilot and standby modes, which enhances the controlled flame output and adequate interplay of connected burners.

Dimensions:

  • Weight: 0.1 lbs
  • Length: 0.5 in
  • Height: 1.5 in
  • Width: 0.75 in

This Part Fits the Following Models

100 models
American Range ARPC-18 American Range ARSB American Range ARSP American Range ARSP-18-2 American Range SPSH-18 APW GGT-18H APW GGT-18I APW GGT-48H APW GHP-H APW GHP-W Bakers Pride 50 SERIES Bakers Pride BPV Bakers Pride CH Bakers Pride CH SERIES Bakers Pride CH-10 Bakers Pride CH-12 Bakers Pride CH-14 Bakers Pride CH-16 Bakers Pride CH-18 Bakers Pride CH-20 Bakers Pride CH-22 Bakers Pride CH-4 Bakers Pride CH-6 Bakers Pride CH-8 Bakers Pride GG Bakers Pride GG SERIES Bakers Pride SERIES 50 Bakers Pride SGBR Bakers Pride SGBR SERIES Bakers Pride SGBR-2 Bakers Pride SGBR-3 Bakers Pride SGBR-4 Bakers Pride SGBR-5 Bakers Pride SGBR-6 Bakers Pride SGBR-7 Bakers Pride XX Bakers Pride XX SERIES Bakers Pride XX-10 Bakers Pride XX-12 Bakers Pride XX-4 Bakers Pride XX-6 Bakers Pride XX-8 Duke AEROHOT Duke FOODWARMER Duke THURMADUKE Garland 40 SERIES Garland 40/50 SERIES Garland 50R SERIES Garland BW6XRN48 Garland C836-36ARC Garland G24 Garland G24-15H Garland G24-15HFSD Garland G24-24G Garland G24-24GFSD Garland G24-24GTH Garland G24-24GTHX Garland G24-36G Garland G24-36GFSD Garland G24-36GTH Garland G24-36GTHX Garland G24-48G Garland G24-48GFSD Garland G24-48GTH Garland G24-48GTHX Garland G24-4L Garland G24-4S Garland G24-4T Garland G24-60G Garland G24-60GFSD Garland G24-60GTH Garland G24-60GTHX Garland G24-72G Garland G24-72GFSD Garland G24-72GTH Garland G24-72GTHX Garland G24-T Garland G286 Garland G30A SERIES Garland G36 Garland G36-6C Garland G36-6R Garland G36-6S Garland G36-6T Garland G36T Garland G48 Garland G48-8CS Garland G48-8LL Garland G48-8RS Garland G48-8SS Garland G48P Garland G48PA Garland G48PD Garland G48PS Garland G48PSA Garland G48PSD Garland G60 Garland G60-10CC Garland G60-10CR Garland G60-10CS
Showing of 100.0

AMERICAN RANGE:

A29302 AMRA29302

ANETS:

ANEP8901-79 P8901-79

APW WYOTT:

2065614

BAKERS PRIDE:

2V-R3021A BKPR3021A R3021A R3021X

DUKE:

3505 3505-2 DUK3505 DUK3505-2

DYNAMIC COOKING SYSTEMS:

13029-2 DCS13029-2

IMPERIAL:

1607 IMP1607

ROYAL RANGE:

1002 1120

Step1: Turn off gas supply and power; allow system to cool completely.

Step2: Remove old pilot valve from connection safely using proper wrench.

Step3: Clean threads and inspect tubing for damage.

Step4: Install new valve, align connections, tighten securely.

Step5: Restore gas, check for leaks with approved solution.

Step6: Test pilot flame adjustment and ensure stable ignition

  • What maintenance is required for the American Range 10436 Adjustment Pilot Valve?

    Inspect the pilot valve regularly for smooth adjustment and secure gas connections. Keep the valve clean and free from grease or debris that may restrict flow. Check for leaks during servicing. Ensure proper calibration for stable pilot flame control and safe operation.

  • What are common issues with the American Range 10436 Adjustment Pilot Valve?

    • Pilot flame difficult to adjust.
    • Gas flow inconsistency.
    • Valve leakage at fittings.
    • Unstable pilot flame.
    • Adjustment knob stiffness or failure.

Customer Reviews

No reviews yet. Be the first to write one!

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More