Vulcan Hart 00-719189 Range Adjustment Pilot Valve 1/8" MPT X 3/16" CCT

SKU: 00-719189 1-00-719189 Brand: Availability:
In Stock
(0)

$7.52


Have a Question? +1 (866) 863-0907

Specifications:

  • Pilot Adjustment Valve
  • [ 1/8" Mpt X 3/16" Cct ] ] [Width 1-1/8"],
  • Straight, Adjustable
  • American Range
  • Bakers Pride Broiler Ch10. Series: 50, Gg, Xx.
  • Dynamic Cooking Systems Broiler Cheesemelter, Salamander.
  • Garland Oven 60/40R, Stw286 & Where Applicable.
  • Griddle Series: Gd
  • Imperial Broiler Eba-3223. Series: Gd, Icb, Icma, Isb, Msq.
  • Grill Series: Imga, Itg.
  • Range Series: Icra, Isp-J, Ispa.
  • Wolf Broiler Cmss Cheesemelter, Fshb & Hbss
  • (Old F & Fs-855), Scb.
  • Grill Gg, Stg.

Description

The Vulcan Hart 00-719189 Range Adjustment Pilot Valve is used to control the flow of the gas to the pilot by adjusting the pressure through the internal valve mechanism. It works by opening or closing the passage of the gas centred on the manual adjustment. This is a part that is fitted in the initial gas line of commercial cooking equipment between the gas supply and the burner assembly. It features a 1/8" MPT by 3/16" CCT connection that allows it to provide proper initial ignition control and stable flame control in gas-powered appliances in foodservice settings.

Dimensions:

  • Weight: 0.1 lbs
  • Length: 0.5 in
  • Height: 1.5 in
  • Width: 0.75 in

This Part Fits the Following Models

100 models
Vulcan Hart 12 Vulcan Hart 148L Vulcan Hart 148LC Vulcan Hart 160L Vulcan Hart 160LC Vulcan Hart 172L Vulcan Hart 172LC Vulcan Hart 24L Vulcan Hart 24S Vulcan Hart 260L Vulcan Hart 260LC Vulcan Hart 260LCC Vulcan Hart 272L Vulcan Hart 272LC Vulcan Hart 272LCC Vulcan Hart 36C Vulcan Hart 36FL Vulcan Hart 36L Vulcan Hart 36LC Vulcan Hart 36S Vulcan Hart 481L Vulcan Hart 481LC Vulcan Hart 48C Vulcan Hart 48L Vulcan Hart 48S Vulcan Hart 48SS Vulcan Hart 60CS Vulcan Hart 60FLC Vulcan Hart 60L Vulcan Hart 60LC Vulcan Hart 60LCC Vulcan Hart 60SC Vulcan Hart 60SS Vulcan Hart 72CC Vulcan Hart 72CS Vulcan Hart 72L Vulcan Hart 72LC Vulcan Hart 72LCC Vulcan Hart 72SC Vulcan Hart 72SS Vulcan Hart ABC36 Vulcan Hart C12 Vulcan Hart C24S Vulcan Hart C36C Vulcan Hart C36S Vulcan Hart C48C Vulcan Hart C48S Vulcan Hart C48SS Vulcan Hart C60CS Vulcan Hart C60SC Vulcan Hart C60SS Vulcan Hart C72CC Vulcan Hart C72CS Vulcan Hart C72SC Vulcan Hart C72SS Vulcan Hart CM60-9 Vulcan Hart CMSS SERIES Vulcan Hart CMSS-36 Vulcan Hart CMSS-48 Vulcan Hart CMSS-60 Vulcan Hart CMSS-72 Vulcan Hart CMSS-84 Vulcan Hart GG Vulcan Hart GH56C Vulcan Hart H56 Vulcan Hart H56C Vulcan Hart MG12 Vulcan Hart SCB SERIES Vulcan Hart SCB-24 Vulcan Hart SCB25 Vulcan Hart SCB30 Vulcan Hart SCB-36 Vulcan Hart SCB-47 Vulcan Hart SCB-60 Vulcan Hart SCB-72 Vulcan Hart SCB84 Vulcan Hart SCB96 Vulcan Hart SPGR-1 Vulcan Hart SPGR-2 Vulcan Hart STG Vulcan Hart STG-48 Vulcan Hart STG-72 Vulcan Hart V24 Vulcan Hart V260 Vulcan Hart V36 Vulcan Hart V36F Vulcan Hart V60 Vulcan Hart V60F Vulcan Hart VAC 25 Vulcan Hart VAC 36 Vulcan Hart VAC 47 Vulcan Hart VAC 60 Vulcan Hart VAC 72 Vulcan Hart VBB2 Vulcan Hart VBI2 Vulcan Hart VCCB25 Vulcan Hart VCCB30 Vulcan Hart VCCB36 Vulcan Hart VCCB47 Vulcan Hart VCCB60
Showing of 100.0

AMERICAN RANGE:

10436 A29302 AMRA29302

ANETS:

ANEP8901-79 P8901-79

APW WYOTT:

2065614

BAKERS PRIDE:

2V-R3021A BKPR3021A R3021A R3021X

DUKE:

3505 3505-2 DUK3505 DUK3505-2

DYNAMIC COOKING SYSTEMS:

13029-2 DCS13029-2

IMPERIAL:

1607 IMP1607

ROYAL RANGE:

1002 1120

Step1: Turn off gas supply and allow system to cool completely.

Step2: Remove old pilot valve and clean threaded connections to remove debris or old sealant.

Step3: Apply approved thread sealant and install new valve securely, aligning threads carefully.

Step4: Reconnect lines and tighten fittings using proper tools.

Step5: Restore gas slowly and check for leaks using soapy solution before full operation.

  • What maintenance is required for the Vulcan Hart 00-719189 Adjustment Pilot Valve?

    Keep valve clean and free of debris to ensure proper gas or fluid regulation. Inspect connections for leaks and tighten fittings regularly. Ensure smooth pilot adjustment and replace worn seals when needed.

  • What are common issues with the Vulcan Hart 00-719189 Adjustment Pilot Valve?

    • Pilot valve sticking due to carbon buildup, causing delayed ignition or difficulty adjusting flow.
    • Inconsistent pressure regulation or weak pilot flame leading to unstable burner performance.
    • Leaks at threaded connections or worn seals resulting in gas loss or unsafe operation.
    • Difficulty in fine adjustment of pilot flow causing uneven burner ignition or shutdown issues.

Customer Reviews

No reviews yet. Be the first to write one!

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More