Specifications:

  • Brass Hood Orifice,
  • 3/8"-27 X 1/2" High X #50
  • American Range Broiler Aecb
  • Garland / Us Range Oven 836 Cuisine (Lp)
  • Imperial Broiler Series: Eba, Irb.
  • Oven Series: Icv, Icvd. (Lp)
  • Star Broiler Where Applicable. Fryer 630F
  • Us Range Broiler Pma/Rb-36, Rb-26.
  • Series: 1000 Front Burner, Rba (Used For Nat Gas).
  • Fryer Rcf-(2424,2448).
  • Oven Series: 836 Cuisine Standard Ovens,
  • Performer Ii Convection Ovens With S/N Beginning With "V".
  • Range Sp-1855 Small Burner, Tr H Shaped Burner.

Description

The ATOSA 301040007 Charbroiler Orifice #50 is a part that regulates the flow of gas to burner ports. The calibrated opening and shape of the brass hood control the amount and direction of gas that is introduced to the burner to maintain, the size and level of the flame and the amount of heat generated. It enters the burner manifold or jet holder and matches with the combustion ports. It assists in the maintenance of a proper flow of gas.

Dimensions:

  • Weight: 0.02 lbs
  • Length: 0.75 in
  • Height: 0.75 in
  • Width: 0.25 in

This Part Fits the Following Models

100 models
Atosa ATCB-24 Atosa ATCB-36 Atosa ATCB-48 Atosa ATRC-24 Atosa ATRC-36 Atosa ATRC-48 American Range ADJ American Range ADJF American Range AECB American Range AERB American Range AMSQ American Range ARB American Range ARCM American Range ARRB American Range ARSM American Range ARSM-24 American Range ARSM-36 APW GGM-18H APW GGM-18I APW GGM-24H APW GGM-24I APW GGM-36H APW GGM-36I APW GGM-48H APW GGM-48I APW GGT-18H APW GGT-18I APW GGT-36H Garland GXRN48 Garland H/P-280 Garland HP-280 SERIES Garland MCO-ED-10 Garland MCO-ED-10-S Garland MCO-ED-20 Garland MCO-ED-20-S Garland MCO-ES-10 Garland MCO-ES-10-S Garland MCO-ES-20 Garland MCO-ES-20-S Garland MCO-GD-10 Garland MCO-GD-10-S Garland MCO-GD-20 Garland MCO-GD-20-S Garland MCO-GS-10 Garland MCO-GS-10-S Garland MCO-GS-20 Garland MCO-GS-20-S Garland SP-1844-2F Garland SP-1844-2S Imperial EBA SERIES Imperial GD SERIES Imperial ICRA-1 Imperial ICRA-2 Imperial ICRA-3 Imperial ICRA-4 Imperial ICRA-5 Imperial ICV Imperial IDR-37 Imperial IDR-49 Imperial IDR-61 Imperial IGT SERIES Imperial IHR Diamond Imperial IHR-6-C Imperial IHR-G24-2-C Imperial IR SERIES Imperial IR-24 Imperial IR-36 Imperial IR-48 Imperial IR-60 Imperial IR-72 Imperial IRB-72 Imperial ISPA-18 Imperial ISPA-18-2 Imperial ISPA-18W Imperial ISPA-18W-2 Royal Range RCOS Royal Range RCOS-2 Royal Range RR-10 Royal Range RR-10G12 Royal Range RR-12 Royal Range RR-24RB-120 Royal Range RR-2G12 Royal Range RR-2G24 Royal Range RR-2G36 Royal Range RR-2G48 Royal Range RR-2G60 Royal Range RR-36RB-126 Royal Range RR-4 Royal Range RR-4-36 Royal Range RR-48RB-126 Royal Range RR-4G12 Royal Range RR-4G24 Royal Range RR-4G36 Royal Range RR-4G48 Royal Range RR4RG12 Royal Range RR-4SU Royal Range RR-6 Royal Range RR-6G12 Royal Range RR-6G24 Royal Range RR-6G36
Showing of 100.0

Step1: Turn off gas supply and electrical power; allow appliance to fully cool before starting.

Step2: Remove burner assembly carefully, then unscrew existing orifice using correct tool.

Step3: Install new orifice, ensuring threads are properly aligned before tightening.

Step4: Tighten securely without over-tightening to prevent damage to components.

Step5: Reassemble burner components and verify alignment for proper gas flow operation.

Step6: Turn gas back on slowly and test all connections using soap solution for leaks.

  • What maintenance is required for the ATOSA 301040007 Orifice?

    Clean the orifice regularly to prevent carbon buildup and gas flow restriction. Ensure tight and proper installation to maintain stable performance. Always turn off the gas supply before performing any maintenance for safety.

  • What are common issues with the ATOSA 301040007 Orifice?

    • Blocked orifice causing weak or uneven flame output.
    • Gas leakage from improper fitting or loose installation.
    • Corrosion of brass affecting performance stability.
    • Irregular combustion leading to ignition delays or flame fluctuations.

Customer Reviews

5 Based on 1 reviews
5 ★
1
4 ★
0
3 ★
0
2 ★
0
1 ★
0
1 review
  • Flow Accurately
    Mike —

    Controls fluid flow accurately and efficiently.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More