Specifications:

  • [ Type- Kxp ] [ Temp 100-450 ] [ Bulb 3/16" X 11-5/8" ]
  • [ Cap 48" ] Vert Bkt, Flat Down,
  • [ Dial For Lang # 22-1278.
  • Montague Griddle Model Delux
  • Lang Broilers: 1B(012,030,C12S,Bo18S), 2B(C24S,O30S),
  • 36S-Sh (Before S/N A67127).
  • Grill G-(24Ti,36Ti,48Ti,60Ti,72Ti), Gc-(24Ti,36Ti,48Ti,
  • 60Ti,72Ti).
  • Ovens: Eco-(8M,9M), Ecco-C (Including Mrs Fields),
  • Ecco-C5S, Ecco-C5S-Cs (Mrs Fields & Schlotskys),
  • Ecco-Lmdr (Cinnabon), Ecco-T, Ehs-C (Including
  • Braums), Ehs-(C-Lmdr,C1-1208Bk,Cir,Cir-Bk,T),
  • F-6S (With S/N C46305 To D90996), F-(6S-M,6Sch-M),

Description

The Lang 2T30402-27 Thermostat is used in different cooking equipment to maintain the temperature at the desired level. This bulb has a 3/16" x 11-5/8" size and a 48" capillary, and operates from 100°F to 450°F. This thermostat is compatible with Lang broilers and griddles, and with several ovens such as the ECO and ECCO series. It is the main component for maintaining heat, preventing heat overage and such optimal cooking conditions as to produce better food quality and long useful life of equipment.

Dimensions:

  • Weight: 0.5 lbs
  • Length: 12 in
  • Height: 2.5 in
  • Width: 2 in

This Part Fits the Following Models

139 models
Lang 224T Lang 224TH Lang 236SHE-NAT Lang 236S-LP Lang 236S-NAT Lang 236T Lang 248T Lang 248TC Lang 260T Lang 272T Lang 9K-HG224T-MG Lang 9P-RT36D-440VG Lang CCOF-AT Lang CCOFLF-AT Lang CLCO-AT Lang CLCOL-AT Lang CR30-AP Lang CR30-PT Lang ECCO-AP Lang ECCO-C Lang ECCO-LMDR Lang ECCO-PP Lang ECCO-PT Lang ECCO-SII Lang ECCO-T Lang ECO-6M Lang ECO-7M Lang ECO-8M Lang ECO-9M Lang ECOD-AT Lang ECODL-AT Lang ECOD-PT Lang ECOF-AT Lang ECOF-C Lang ECOF-C-CN Lang ECOFL-AT Lang ECOF-PT Lang ECOF-T Lang ECOH-2/4CECN Lang ECOH-C2/3VCN Lang ECOH-C2/4VCN Lang ECOH-C208CNF Lang ECOH-C208VCN Lang ECOH-C240VCN Lang ECOH-C480VCN Lang ECOH-C-CN Lang ECOH-PP Lang ECOH-PT Lang ECSF-ES Lang ECSF-EZ Lang EHS-C Lang EHS-CIR Lang EHS-LMDR Lang EHS-PP Lang EHS-PT Lang EHS-T Lang F-11 Lang F-6 Lang FCOF-AT Lang FCOFAT480SUB Lang FCOFL-AT Lang G-24T Lang G-24TDSI Lang G-24TI Lang G-2TDSI Lang G-2TI Lang G-36T Lang G-36TDSI Lang G-36TI Lang G-3TDSI Lang G-3TI Lang G-48T Lang G-48TDSI Lang G-48TI Lang G-4TDSI Lang G-4TI Lang G-5TDSI Lang G-5TI Lang G-60T Lang G-60TDSI Lang G-60TI Lang G-60TI-N Lang G-6TDSI Lang G-6TI Lang G-72T Lang G-72TDSI Lang G-72TI Lang GC-24T Lang GC-24TI Lang GC-36T Lang GC-36TI Lang GC-48T Lang GC-48TI Lang GC-60T Lang GC-60TI Lang GC-72T Lang GC-72TI Lang GCCO-A Lang GCCO-C Lang GCCO-PP Lang GCCO-PT Lang GCCO-T Lang GCOF-PP Lang GCOF-PP-NAT Lang GCOF-T Lang GGB-24TI Lang GGB-36TI Lang GGB-48TI Lang GHS-T Lang RCOH-AP Lang RCOHAP-208V Lang RCOH-PT Lang RCOHRAP208KR Lang RCOHRAP-480M Lang RCOHRAP-480V Lang RF21S Lang RF21S-A Lang RF21S-C Lang RF21S-D Lang RF21S-G Lang RF21S-H Lang RF21SMG-USUB Lang RF21S-XLH Lang RF42S Lang RF42S-XLH Lang RT30S-CF Lang SCR30 Lang TCR-30 Lang TRE36C1 Lang TRE36C2 Lang TRE36C3 Lang TRE36C4 Lang TRE36C5 Montague DG2424-SAT Montague DG2436-SAT Montague DG2448-SAT Montague DG2460-SAT Montague DG2472-SAT Star Mfg 260TC
Showing of 139.0

MONTAGUE:

29023-8

STAR MFG:

2T-30402-27 30402-27

STERO:

STA2T-30402-27 STA2T30402-27 STA30402-27

U-LINE:

KXP356-48

Step1: Turn off all electrical and gas supply and confirm the unit is fully cooled before starting work.

Step2: Remove the control panel and trace and label all wiring connected to the old thermostat.

Step3: Disconnect wiring and gently remove the existing thermostat and capillary bulb assembly.

Step4: Install the new thermostat with vertical bracket and position the flat-down bulb in the correct sensing placed.

Step5: Reconnect wiring, secure the without kinks, reinstall panel, restore power, and test temperature control accuracy.

  • What maintenance is required for the Lang 2T30402-27 Thermostat?

    Clean the sensing bulb and surrounding area to prevent grease buildup. Inspect the capillary tube for bends or leaks and ensure secure mounting. Verify calibration regularly for accurate temperature control. Avoid physical stress on the bulb assembly.

  • What are common issues with the Lang 2T30402-27 Thermostat?

    • Inaccurate temperature readings from calibration drift or sensor damage.
    • Failure to heat or cycle due to faulty switch contacts.
    • Damaged capillary tube causing loss of control response.
    • Erratic operation from loose mounting or electrical connection issues.